1. Main Motor and Transmission System
Common Faults: Unstable main motor current fluctuations, motor failure to start, excessive bearing temperature rise, abnormal gearbox noise.
Causes: Uneven feeding, poor bearing lubrication/wear, burnt-out fuses, insufficient lubricating oil, or blocked suction pipe.
2. Extruder Screw and Barrel
Common Faults: Sudden drop in extrusion volume, material slippage and failure to advance, uneven plasticization.
Causes: Long-term wear of the screw leading to excessive clearance, material contamination by hard foreign objects, malfunction of a section of the barrel heater.
3. Die Head and Mold
Common Faults: Poor material discharge/blockage, yellow-black lines on the profile surface, material stagnation and carbon buildup in the flow channel.
Causes: Localized temperature runaway, dead zones in the flow channel design, failure to promptly clean residual material leading to degradation.
4. Auxiliary Equipment Components
Common Faults: No negative pressure in the vacuum system, traction slippage, uneven cutting surfaces.
Causes: Vacuum pump pipeline blockage/leakage, worn traction rollers, dull or worn cutting blades not replaced in time.
5. Temperature Control and Electrical System
Common Faults: Excessive temperature deviation, false triggering of over-temperature alarm.
Causes: Aging and misalignment of thermocouples, open circuit in heating coils, drift in temperature control module parameters.